HIV 1/2 Human Immunodeficiency Virus Rapid Test Device Package Insert

Looking for HIV 1/2 Rapid Test Devices? Look no further! As a factory, we offer high-quality products with accurate results. Buy now for reliable HIV testing!

Request a Quote
  • HIV 1/2 Human Immunodeficiency Virus Rapid Test Device Package Insert

PRODUCTS DETAILS

HIV is the etiologic agent of Acquired Immune Deficiency Syndrome (AIDS). The virion is surrounded by a lipid envelope that is derived from host cell membrane. Several viral glycoproteins are on the envelope. Each virus contains two copies of positive-sense genomic RNAs. HIV 1 has been isolated from patients with AIDS and AIDS-related complex, and from healthy people with high potential risk for developing AIDS.1 HIV 2 has been isolated from West African AIDS patients and from seropositive asymptomatic individuals.2 Both HIV 1 and HIV 2 elicit immune response.3 Detection of HIV antibodies in serum, plasma or whole blood is the most efficient and common way to determine whether an individual has been exposed to HIV and to screen blood and blood products for HIV.4 Despite of the differences in their biological characters, serological activities and genome sequences, HIV 1 and HIV 2 show strong antigenic cross-reactivity.5,6 Most HIV 2 positive sera can be identified by using HIV 1 based serological tests. The HIV 1/2 Human Immunodeficiency Virus Rapid Test Device (Whole Blood/Serum/Plasma) is a rapid test to qualitatively detect the presence of antibody to HIV 1 and/or HIV 2 in whole blood, serum or plasma specimen. The test utilizes latex conjugate and multiple recombinant HIV proteins to selectively detect antibodies to the HIV 1/2 in whole blood, serum or plasma. 1.Chang, SY, Bowman, BH, Weiss, JB, Garcia, RE and White, TJ. The origin of HIV-1 isolate HTLV-IIIB. Nature (1993) 3;363:466-9 2.Arya, SK, Beaver, B, Jagodzinski, L, Ensoli, B, Kanki, PJ,Albert, J, Fenyo, EM, Biberfeld, G, Zagury, JF and Laure, F. New human and simian HIV-related retroviruses possess functional transactivator (tat) gene. Nature (1987) 328:548-550 3.Caetano JA Immunologic aspects of HIV infection. Acta Med Port (1991) 4 Suppl 1:52S-58S 4.Janssen, RS, Satten, GA, Stramer, SL, Rawal, BD, O'Brien, TR, Weiblen, BJ, Hecht, FM, Jack, N, Cleghorn, FR, Kahn, JO, Chesney, MA and Busch MP. New testing strategy to detect early HIV-1 infection for use in incidence estimates and for clinical and prevention purposes. JAMA (1998) 280(1):42-48 5.Travers, K, Mboup, S, Marlink, R, Gueye-Nidaye, A, Siby, T, Thior, I, Traore, I, Dieng-Sarr, A, Sankale, JL and Mullins, C. Natural protection against HIV-1 infection provided by HIV-2. Science (1995) 268:1612-1615 6.Greenberg, AE, Wiktor, SZ, DeCock, KM, Smith, P, Jaffe HW and Dondero, TJ, Jr. HIV-2 and natural protection against HIV-1 infection. Science (1996) 272:1959-1960 The kit can be stored at room temperature or refrigerated (2-30°C). The test device is stable through the expiration date printed on the sealed pouch. The test device must remain in the sealed pouch until use. DO NOT FREEZE. Do not use beyond the expiration date.★ The HIV 1/2 Human Immunodeficiency Virus Rapid Test Device (Whole Blood/Serum/Plasma) can be performed using whole blood (from venipuncture or fingerstick), serum, or plasma. ★ To collect Fingerstick Whole Blood specimens:   Wash the patient’s hand with soap and warm water or clean with an alcohol swab. Allow to dry.   Puncture the skin with a sterile lancet. Wipe away the first sign of blood.   Gently rub the hand from wrist to palm to finger to form a rounded drop of blood over the puncture site.   Add the Fingersitck Whole Blood specimen to the test device by using a capillary tube or hanging drop. ★ Separate serum or plasma from blood as soon as possible to avoid hemolysis. Use only clear, non-hemolyzed specimens. ★ Testing should be performed immediately after specimen collection. Do not leave the specimens at room temperature for prolonged periods. Serum and plasma specimens may be stored at 2-8°C for up to 3 days. For long term storage, specimens should be kept below -20°C. Whole blood collected by venipuncture should be stored at 2-8°C if the test is to be run within 2 days of collection. Do not freeze whole blood specimens. Whole blood collected by fingerstick should be tested immediately. ★ Bring specimens to room temperature prior to testing. Frozen specimens must be completely thawed and mixed well prior to testing. Specimens should not be frozen and thawed repeatedly. ★ If specimens are to be shipped, they should be packed in compliance with federal regulations covering the transportation of etiologic agents.
Test devices Disposable specimen droppers
Buffer Package insert
POSITIVE RESULT:
table_img

* A colored band appears in the control band region (C) and another colored band appears in the T band region.
NEGATIVE RESULT:
table_img

One colored band appears in the control band region (C). No band appears in the test band region (T).
INVALID RESULT:
table_img

Control band fails to appear. Results from any test which has not produced a control band at the specified reading time must be discarded. Please review the procedure and repeat with a new test. If the problem persists, discontinue using the kit immediately and contact your local distributor.
1.The HIV 1/2 Human Immunodeficiency Virus Rapid Test Device (Whole Blood/Serum/Plasma) is for in vitro diagnostic use only. This test should be used for the detection of antibodies to HIV in whole blood, serum or plasma. Neither the quantitative value or the rate of increase in HIV antibody concentration can be determined by this qualitative test. 2.This test will only indicate the presence of antibodies to HIV in the specimen and should not be used as the sole criteria for the diagnosis of HIV 1 and/or HIV 2 infection. 3.For confirmation, further analysis of the specimens should be performed, such as ELISA and/or Western Blot analysis. 4.As with all diagnostic tests, all results must be interpreted together with other clinical information available to the physician. 5.If the test result is negative and clinical symptoms persist, additional follow up tests using other clinical methods are recommended. A negative result at any time does not preclude the possibility of HIV 1 and/or HIV 2 infection.

Method

EIA

Total Results

HIV 1/2

Rapid Test Device

Results

Positive

Negative

Positive

554

4

558

Negative

0

1159

1159

Total Results

554

1163

1717

Specimen collection containers Lancets (for fingerstick whole blood only)
Centrifuge (for plasma only) Timer
Disposable heparinized capillary tubes and dispensing bulb (for fingerstick whole blood only)
The HIV 1/2 Human Immunodeficiency Virus Rapid Test Device (Whole Blood/Serum/Plasma) has been compared with a leading commercial HIV EIA test. The correlation between these two systems is 99.8%.Sensitivity The HIV 1/2 Human Immunodeficiency Virus Rapid Test Device (Whole Blood/Serum/Plasma) has been tested by anti-HIV 1 low titer performance panel, anti-HIV 2 performance panel and anti-HIV 1 seroconversion panel (Boston Biomedica, Inc.). And it has also been compared with leading commercial EIA HIV test on clinical specimens. The results show that HIV 1/2 Human Immunodeficiency Virus Rapid Test Device (Whole Blood/Serum/Plasma) is very sensitive to HIV 1 and/or HIV 2 antibodies. Specificity The specificity of the test is comparable to a leading commercial HIV EIA test. The HIV 1/2 Human Immunodeficiency Virus Rapid Test Device (Whole Blood/Serum/Plasma) is highly specific for anti-HIV 1 and/or HIV 2 compared to a leading commercial HIV EIA test.The HIV 1/2 Human Immunodeficiency Virus Rapid Test Device (Whole Blood/Serum/Plasma) is a qualitative, membrane based immunoassay for the detection of antibodies to HIV 1/2 in whole blood, serum or plasma. The membrane is pre-coated with recombinant HIV antigens. During testing, the whole blood, serum or plasma specimen reacts with HIV antigen coated particles in the test strip. The mixture then migrates upward on the membrane chromatographically by capillary action and reacts with recombinant HIV antigen on the membrane in the test line region. If the specimen contains antibodies to HIV 1 and/or HIV 2, a colored line will appear in the test line region indicating a positive result. If the specimen does not contain HIV 1 and/or HIV 2 antibodies, a colored line will not appear in the test line region indicating a negative result. To serve as a procedural control, a colored line will always appear in the control line region indicating that proper volume of specimen has been added and membrane wicking has occurred. ★ For professional in vitro diagnostic use only. Do not use after expiration date. ★ Do not eat, drink or smoke in the area where the specimens or kits are handled. ★ Handle all specimens as if they contain infectious agents. Observe established precautions against microbiological hazards throughout testing and follow the standard procedures for proper disposal of specimens. ★ Wear protective clothing such as laboratory coats, disposable gloves and eye protection when specimens are being tested. ★ Humidity and temperature can adversely affect results.Internal procedural controls are included in the test. A colored line appearing in the control region (C) is an internal positive procedural control. It confirms sufficient specimen volume and correct procedural technique. Control standards are not supplied with this kit; however, it is recommended that positive and negative controls be tested as a good laboratory practice to confirm the test procedure and to verify proper test performance.Allow the test device, specimen, buffer, and/or controls to equilibrate to room temperature (15-30°C) prior to testing. 1.Remove the test device from the foil pouch and use it as soon as possible. Best results will be obtained if the assay is performed within one hour. 2.Place the test device on a clean and level surface. Hold the dropper vertically and transfer 2 drops of specimen (approximately 80 L) to the specimen well (S) of the test device, then add 1 drop of buffer (approximately 40 L) and start the timer. 3.Wait for the colored line(s) to appear. The result should be read at 10 minutes. Do not interpret results after 20 minutes.The intensity of the color in the test line region (T) will vary depending on the concentration of HIV antibodies present in the specimen. Therefore, any shade of colored in the test region (T) should be considered positive.Relative Sensitivity: 99.9% (99.3%-100.0%)*Relative Specificity: 99.6% (99.1%-99.9%)* Relative Accuracy: 99.8% (99.4%-99.9%)*Intra Assay Within-run precision has been determined by using 15 replicates of three specimens: a negative, a low positive and a high positive. The negative, low positive and high positive values were correctly identified 99.5% of the time. Inter-Assay Between-run precision has been determined by 15 independent assays on the same three specimens: a negative, a low positive and a high positive. Three different lots of the HIV 1/2 Human Immunodeficiency Virus Rapid Test Device (Whole Blood/Serum/Plasma) have been tested using negative, low positive and high positive specimens. The specimens were correctly identified 99.5% of the time.

Hot Products

PSA Prostate Specific Antigen Rapid Test Device Package Insert

PSA Prostate Specific Antigen Rapid Test Device Package Insert

Drugs of Abuse Integrated Cup(Urine)

Drugs of Abuse Integrated Cup(Urine)

AMP/BAR/BZO/COC/MOP/THC Test Panel

AMP/BAR/BZO/COC/MOP/THC Test Panel

HCV Rapid Test Device Package Insert

HCV Rapid Test Device Package Insert

Himedic COVID-19 Neutralizing Antibody Rapid Test Cassette

Himedic COVID-19 Neutralizing Antibody Rapid Test Cassette

HCG One Step Pregnancy Test Device Package Insert

HCG One Step Pregnancy Test Device Package Insert

LH One Step Ovulation  Test Device Package Insert

LH One Step Ovulation Test Device Package Insert

Influenza A+b & COVID-19 Ag Combo Test Cassette

Influenza A+b & COVID-19 Ag Combo Test Cassette

HIMEDIC  COVID-19 Antigen Rapid Test Kit (SALIVA)

HIMEDIC COVID-19 Antigen Rapid Test Kit (SALIVA)

Drugs of Abuse Integrated Cup(Urine)

Drugs of Abuse Integrated Cup(Urine)

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours